600 W High-Voltage DC Power Module for Huawei CloudEngine (CE) 8800,7800, 6800, and 5800 Series switches

Huawei Data Center Switch includes CloudEngine CE12800, CE12800E, CE1800V, CE5800, CE6800, CE7800, CE8800 Series. In this article, HongTelecom will introduce the 600 W High-Voltage DC Power Module (PHD-600WA-B & PHD-600WA-F) for CE8800 & CE7800 & CE6800 & CE5800 series switches.

600 W High-Voltage DC Power Module

Version Mapping

600 W high-voltage DC power modules are classified into two types depending on the airflow designs: PHD-600WA-B (back-to-front airflow, air exhaust on power module panel) and PHD-600WA-F (F: front-to-back airflow, air intake on power module panel).

Table 1 describes the mapping between switch models and 600 W high-voltage DC power modules.

Table 1 Version mapping
Switch Model PHD-600WA-B PHD-600WA-F
CE6850-48S6Q-HI Supported in V100R005C00 and later versions Supported in V100R005C00 and later versions
CE6850U-48S6Q-HI

CE6850-48T6Q-HI

CE6850U-24S2Q-HI

Supported in V100R005C10 and later versions Supported in V100R005C10 and later versions
CE6855-48T6Q-HI Supported in V200R001C00 and later versions Supported in V200R001C00 and later versions
CE6856-48T6Q-HI Supported in V200R002C50 and later versions Supported in V200R002C50 and later versions
CE6875-48S4CQ-EI Supported in V200R003C00 and later versions Supported in V200R003C00 and later versions

Appearance

Figure 1 shows the appearance of a PHD-600WA-B power module, and Figure 2 shows the appearance of a PHD-600WA-F power module.

Figure 1 PHD-600WA-B power module

Figure 1 PHD-600WA-B power module

Figure 2 PHD-600WA-F power module

Figure 2 PHD-600WA-F power module

Function

PHD-600WA-B and PHD-600WA-F power modules use different airflow designs but have the same functions. Table 2 describes the functions of them.

Table 2 Functions of 600 W high-voltage DC power modules
Function Description
Input protection Input overvoltage protection and undervoltage protection In either of the two protection states, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply.
Input overcurrent protection In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range.
Output protection Output overvoltage protection In this protection state, the power module stops supplying power intermittently. When the system recovers from output overvoltage, the power module automatically resumes power supply.
Output overcurrent protection In this protection state, the power module supplies power intermittently. When the output current is limited within a range, the power module automatically resumes power supply.
Output short-circuit protection In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply.
Overtemperature protection When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply.
Heat dissipation
  • PHD-600WA-B: back-to-front airflow
  • PHD-600WA-F: front-to-back airflow
Hot swap Supported
 NOTE:
When a power module enters overtemperature protection state, take measures to lower the ambient temperature. The power module can automatically resume power supply when the temperature falls within the normal range.

Panel

Figure 3 and Figure 4 show the panels of 600 W high-voltage DC power modules.

Figure 3 PHD-600WA-B panel

Figure 3 PHD-600WA-B panel

Figure 4 PHD-600WA-F panel

Figure 4 PHD-600WA-F panel

1. Lock 2. Indicator 3. Fan air vent 4. Handle

NOTE:
Each 600 W high-voltage DC power module is delivered with a velcro strap on the handle. This velcro strap is used to bundle the power cable to the handle.
5. Airflow flag

  • : back-to-front airflow
  • : front-to-back airflow
6. Power socket

Table 3 describes the indicator on a 600 W high-voltage DC power module panel.

Table 3 Indicator description
Indicator Color Description
STAT: running status indicator Off: The power module receives no power input.
Green
  • Steady on: The power module is working normally.
  • Blinking: The power module is in loading or standby state, or the power cable has been connected but the power module is not installed in the switch.
Red
Steady on:

  • Fans of the power module fail.
  • The power module is in overtemperature protection state.
  • The power input is abnormal (input undervoltage or input overvoltage).
  • The power output is abnormal (output overcurrent, output short-circuit, or output overvoltage).

Specifications

Table 4 lists technical specifications of 600 W high-voltage DC power modules.

 NOTE:The PHD-600WA series are no longer sold since August 10, 2018.
Table 4 Technical specifications
Item PHD-600WA-B PHD-600WA-F
Dimensions (W x D x H) 66.0 mm x 340.0 mm x 39.6 mm (2.6 in. x 13.4 in. x 1.6 in.)
Weight 1.5 kg (3.31 lb)
Rated voltage range of 380 V high-voltage DC power input 240 V DC to 380 V DC
Maximum voltage range of 380 V high-voltage DC power input 188 V DC to 400 V DC
Rated input current 4 A
Rated output current 50 A
Rated output voltage 12 V
Rated output power 600 W
Part Number 02310YQQ 02310YQR

 

As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei router and switch and all cards at very good price, also HongTelecom ship to worldwide with very fast delivery.

For related articles, visit the HongTelecom Blog and HongTelecom WordPress.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.

何诗名片

600 W AC&240 V DC Power Module for Huawei CloudEngine (CE) 8800,7800, 6800, and 5800 Series switches

Huawei Data Center Switch includes CloudEngine CE12800, CE12800E, CE1800V, CE5800, CE6800, CE7800, CE8800 Series. In this article, HongTelecom will introduce the 600 W AC Power Module (PAC-600WA-B & PAC-600WA-F) for CE8800 & CE7800 & CE6800 & CE5800 series switches.

600 W AC&240 V DC Power Module

Version Mapping

600 W AC&240 V DC power modules can receive AC inputs or 240 V high-voltage inputs. They are classified into two types depending on the airflow designs: PAC-600WB-B (back-to-front airflow, air exhaust on power module panel) and PAC-600WB-F (F: front-to-back airflow, air intake on power module panel).

Table 1 describes the mapping between switch models and 600 W AC&240 V DC power modules.

Table 1 Version mapping
Switch Model PAC-600WB-B PAC-600WB-F
CE6850-48S6Q-HI Supported in V100R005C00 and later versions Supported in V100R005C00 and later versions
CE6850U-48S6Q-HI

CE6850-48T6Q-HI

CE6850U-24S2Q-HI

Supported in V100R005C10 and later versions Supported in V100R005C10 and later versions
CE6855-48T6Q-HI Supported in V200R001C00 and later versions Supported in V200R001C00 and later versions
CE6856-48T6Q-HI Supported in V200R002C50 and later versions Supported in V200R002C50 and later versions
CE6875-48S4CQ-EI Supported in V200R003C00 and later versions Supported in V200R003C00 and later versions

Appearance

Figure 1 shows the appearance of a PAC-600WB-B power module, and Figure 2 shows the appearance of a PAC-600WB-F power module.

Figure 1 PAC-600WB-B power module

Figure 1 PAC-600WB-B power module

Figure 2 PAC-600WB-F power module

Figure 2 PAC-600WB-F power module

Function

PAC-600WB-B and PAC-600WB-F power modules use different airflow designs but have the same functions. Table 2 describes the functions of them.

Table 2 Functions of a 600 W AC&240 V DC power module

Function

Description

Input protection Input overvoltage protection and undervoltage protection In either of the two protection states, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply.
Input overcurrent protection In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range.
Output protection Output overvoltage protection In this protection state, the power module stops supplying power intermittently. When the system recovers from output overvoltage, the power module automatically resumes power supply.
Output overcurrent protection In this protection state, the power module supplies power intermittently. When the output current is limited within a range, the power module automatically resumes power supply.
Output short-circuit protection In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply.
Overtemperature protection When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply.

Heat dissipation

  • PAC-600WB-B: back-to-front airflow
  • PAC-600WB-F: front-to-back airflow

Hot swap

Supported

 NOTE:
When a power module enters overtemperature protection state, take measures to lower the ambient temperature. The power module can automatically resume power supply when the temperature falls within the normal range.

Panel

Figure 3 and Figure 4 show the panels of 600 W AC&240 V DC power modules.

Figure 3 PAC-600WB-B panel

Figure 3 PAC-600WB-B panel

Figure 4 PAC-600WB-F panel

Figure 4 PAC-600WB-F panel

1. Lock 2. Indicator 3. Fan air vent 4. Handle

NOTE:
Each 600 W AC&240 V DC power module is delivered with a velcro strap on the handle. This velcro strap is used to bundle the power cable to the handle.
5. Airflow flag

  • : back-to-front airflow
  • : front-to-back airflow
6. Power socket

Table 3 describes the indicator on a 600 W AC&240 V DC power module.

Table 3 Indicator description
Indicator Color Description
STAT: running status indicator Off: The power module receives no power input.
Green
  • Steady on: The power module is working normally.
  • Blinking: The power module is in loading or standby state, or the power cable has been connected but the power module is not installed in the switch.
Red
Steady on:

  • Fans of the power module fail.
  • The power module is in overtemperature protection state.
  • The power input is abnormal (input undervoltage or input overvoltage).
  • The power output is abnormal (output overcurrent, output short-circuit, or output overvoltage).

Specifications

Table 4 lists technical specifications of 600 W AC&240 V DC power modules.

Table 4 Technical specifications

Item

PAC-600WB-B PAC-600WB-F
Dimensions (W x D x H) 66.0 mm x 340.0 mm x 39.6 mm (2.6 in. x 13.4 in. x 1.6 in.)
Weight 1.5 kg (3.31 lb)
Rated AC input voltage range 100-240 V AC, 50/60 Hz
Maximum AC input voltage range 90-290 V AC, 47-63 Hz
Rated voltage range of 240 V high-voltage DC power input 240 V DC
Maximum voltage range of 240 V high-voltage DC power input 188-290 V DC
Rated input current
  • 8 A (100 V AC to 240 V AC)
  • 4 A (240 V DC)
Rated output current 50 A
Rated output voltage 12 V
Rated output power 600 W
Part Number 02310YQN 02310YQP

As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei router and switch and all cards at very good price, also HongTelecom ship to worldwide with very fast delivery.

For related articles, visit the HongTelecom Blog and HongTelecom WordPress.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.

何诗名片

 

 

Overview for Huawei CloudEngine (CE) 8800,7800, 6800, and 5800 Series switches

Huawei Data Center Switch includes CloudEngine CE12800, CE12800E, CE1800V, CE5800, CE6800, CE7800, CE8800 Series. In this article, HongTelecom will introduce the Overview for CE12800CE8800CE7800CE6800CE5800 series switches.

Version Mapping

Table 1 lists the power modules and fan modules applicable to different CE8800&7800&6800&5800 series switches and version support for these modules.

Table 1 Applicable power modules, fan modules, and version support
Series Model Power Module Fan Module
CE8800 CE8860-4C-EI

CE8861-4C-EI

CE8868-4C-EI

CE8850-64CQ-EI

1200 W AC&240 V DC power modules:

  • PAC-1K2WA-B (P means power module and AC means alternating current; B means back-to-front airflow, air exhaust on power module panel.)
  • PAC-1K2WA-F (F means front-to-back airflow, air intake on power module panel.)
  • FAN-180A-B
  • FAN-180A-F
1200 W high-voltage DC power modules:

  • PHD-1K2WA-B
  • PHD-1K2WA-F
1200 W DC power modules:

  • PDC-1K2WA-B
  • PDC-1K2WA-F
CE8850-32CQ-EI 600 W AC power modules:

  • PAC-600WA-B
  • PAC-600WA-F
  • FAN-40HA-B
  • FAN-40HA-F
CE7800 CE7850-32Q-EI

CE7855-32Q-EI

600 W AC power modules:

  • PAC-600WA-B
  • PAC-600WA-F
  • FAN-40HA-B
  • FAN-40HA-F
CE6800 CE6850-48S4Q-EI 350 W AC power modules:

  • PAC-350WA-B
  • PAC-350WA-F
  • FAN-40EA-B
  • FAN-40EA-F
350 W DC power modules:

  • PDC-350WA-B (DC means direct current)
  • PDC-350WA-F
CE6850-48T4Q-EI 350 W AC power modules:

  • PAC-350WA-B
  • PAC-350WA-F
NOTE:
600 W AC power modules are recommended for the CE6850-48T4Q-EI of V100R002C00 or a later version.
  • FAN-40EA-B
  • FAN-40EA-F
600 W AC power modules:

  • PAC-600WA-B
  • PAC-600WA-F
CE6850-48S6Q-HI

CE6850U-48S6Q-HI

CE6850-48T6Q-HI

CE6850U-24S2Q-HI

CE6855-48T6Q-HI

CE6856-48T6Q-HI

CE6875-48S4CQ-EI

600 W AC&240 V DC power modules:

  • PAC-600WB-B
  • PAC-600WB-F
  • FAN-060A-B
  • FAN-060A-F
600 W high-voltage DC power modules:

  • PHD-600WA-B
  • PHD-600WA-F
NOTE:
The PHD-600WA series are no longer sold since August 10, 2018.
1200 W high-voltage DC power modules:

  • PHD-1K2WA-B
  • PHD-1K2WA-F
1200 W DC power modules:

  • PDC-1K2WA-B
  • PDC-1K2WA-F
CE6810-48S4Q-EI

CE6810-48S4Q-LI

CE6810-48S-LI

CE6810-32T16S4Q-LI

CE6810-24S2Q-LI

CE6851-48S6Q-HI

CE6855-48S6Q-HI

CE6856-48S6Q-HI

350 W DC power modules:

  • PDC-350WA-B
  • PDC-350WA-F
  • FAN-40EA-B
  • FAN-40EA-F
600 W AC power modules:

  • PAC-600WA-B
  • PAC-600WA-F
CE6860-48S8CQ-EI

CE6865-48S8CQ-EI

CE6870-24S6CQ-EI

CE6870-48S6CQ-EI

CE6880-24S4Q2CQ-EI

CE6880-48S4Q2CQ-EI

350 W DC power modules:

  • PDC-350WA-B
  • PDC-350WA-F
  • FAN-40HA-B
  • FAN-40HA-F
600 W AC power modules:

  • PAC-600WA-B
  • PAC-600WA-F
CE6870-48T6CQ-EI

CE6880-48T4Q2CQ-EI

600 W AC power modules:

  • PAC-600WA-B
  • PAC-600WA-F
  • FAN-40HA-B
  • FAN-40HA-F
CE5800 CE5850-48T4S2Q-EI

CE5850-48T4S2Q-HI

150 W AC power module: PAC-150WA
  • FAN-40EA-B
  • FAN-40EA-F
350 W DC power modules:

  • PDC-350WA-B
  • PDC-350WA-F
CE5810-24T4S-EI

CE5810-48T4S-EI

150 W AC power module: PAC-150WA
  • FAN-40SB-B
  • FAN-40SB-F
350 W DC power modules:

  • PDC-350WA-B
  • PDC-350WA-F
CE5855-48T4S2Q-EI

CE5855-24T4S2Q-EI

150 W AC power module: ES0W2PSA0150
  • FAN-040A-B
  • FAN-040A-F
350 W DC power modules:

  • PDC-350WA-B
  • PDC-350WA-F

Specifications

Table 2 lists specifications of the CE8800&7800&6800&5800 series switches.

Table 2 Specifications of the CE8800&7800&6800&5800 series switches
Item Description
Physical specifications
  • Dimensions (W x D x H):
    • CE8860-4C-EI: 442.0 mm x 600.0 mm x 88.1 mm
    • CE8861-4C-EI: 442.0 mm x 600.0 mm x 88.1 mm
    • CE8868-4C-EI: 442.0 mm x 600.0 mm x 88.1 mm
    • CE8850-64CQ-EI: 442.0 mm x 600.0 mm x 88.1 mm
    • CE8850-32CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE7850-32Q-EI: 442.0 mm x 607.0 mm x 43.6 mm
    • CE7855-32Q-EI: 442.0 mm x 607.0 mm x 43.6 mm
    • CE6810-48S4Q-EI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6810-48S4Q-LI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6810-48S-LI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6810-32T16S4Q-LI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6810-24S2Q-LI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6850-48S4Q-EI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6850-48T4Q-EI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6850-48S6Q-HI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6850-48T6Q-HI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6850U-24S2Q-HI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6850U-48S6Q-HI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6851-48S6Q-HI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6855-48S6Q-HI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6855-48T6Q-HI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6856-48S6Q-HI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6856-48T6Q-HI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6860-48S8CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6865-48S8CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6870-24S6CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6870-48S6CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6870-48T6CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6875-48S4CQ-EI: 442.0 mm x 600.0 mm x 43.6 mm
    • CE6880-24S4Q2CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6880-48S4Q2CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE6880-48T4Q2CQ-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE5810-24T4S-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE5810-48T4S-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE5850-48T4S2Q-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE5850-48T4S2Q-HI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE5855-48T4S2Q-EI: 442.0 mm x 420.0 mm x 43.6 mm
    • CE5855-24T4S2Q-EI: 442.0 mm x 420.0 mm x 43.6 mm
  • Weight (with two power modules and two fan modules, calculated based on the heaviest model if multiple models are supported):
    • CE8860-4C-EI: 21.2 kg
    • CE8861-4C-EI: 21.3 kg
    • CE8868-4C-EI: 21.3 kg
    • CE8850-64CQ-EI: 21.2 kg
    • CE8850-32CQ-EI: 9.0 kg
    • CE7850-32Q-EI: 11.2 kg
    • CE7855-32Q-EI: 11.2 kg
    • CE6810-48S4Q-EI: 10.4 kg
    • CE6810-48S4Q-LI: 10.4 kg
    • CE6810-48S-LI: 10.2 kg
    • CE6810-32T16S4Q-LI: 8.5 kg
    • CE6810-24S2Q-LI: 10.1 kg
    • CE6850-48S4Q-EI: 11.05 kg
    • CE6850-48T4Q-EI: 11.35 kg
    • CE6850-48S6Q-HI: 11.6 kg
    • CE6850-48T6Q-HI: 12.6 kg
    • CE6850U-24S2Q-HI: 12.3 kg
    • CE6850U-48S6Q-HI: 12.6 kg
    • CE6851-48S6Q-HI: 8.7 kg
    • CE6855-48S6Q-HI: 8.7 kg
    • CE6855-48T6Q-HI: 12.6 kg
    • CE6856-48S6Q-HI: 8.7 kg
    • CE6856-48T6Q-HI: 12.6 kg
    • CE6860-48S8CQ-EI: 8.8 kg
    • CE6865-48S8CQ-EI: 8.8 kg
    • CE6870-24S6CQ-EI: 8.4 kg
    • CE6870-48S6CQ-EI: 8.6 kg
    • CE6870-48T6CQ-EI: 9.8 kg
    • CE6875-48S4CQ-EI: 12.6 kg
    • CE6880-24S4Q2CQ-EI: 8.5 kg
    • CE6880-48S4Q2CQ-EI: 8.7 kg
    • CE6880-48T4Q2CQ-EI: 9.0 kg
    • CE5810-24T4S-EI: 8.0 kg
    • CE5810-48T4S-EI: 8.2 kg
    • CE5850-48T4S2Q-EI: 8.85 kg
    • CE5850-48T4S2Q-HI: 8.8 kg
    • CE5855-48T4S2Q-EI: 8.4 kg
    • CE5855-24T4S2Q-EI: 8.1 kg
Environment parameters Temperature
  • Operating temperature: 0°C to 40°C (0 m to 1800 m)
    NOTE:
    When the altitude is between 1800 m and 5000 m, the operating temperature reduces by 1°C every time the altitude increases by 220 m.
  • Storage temperature: -40°C to +70°C
Relative humidity 5% RH to 95% RH, noncondensing
Altitude < 5000 m
Power parameters Power input type AC/DC/high-voltage DC
AC power input
  • Rated input voltage range:
    • CE8860-4C-EI, CE8861-4C-EI, CE8868-4C-EI, and CE8850-64CQ-EI: 100 V AC to 130 V AC/200 V AC to 240 V AC, 50/60 Hz
    • Other models: 100 V AC to 240 V AC, 50/60 Hz
  • Maximum input voltage range:
    • CE5855-48T4S2Q-EI and CE5855-24T4S2Q-EI: 90 V AC to 264 V AC, 47 Hz to 63 Hz
    • Other models: 90 V AC to 290 V AC, 47 Hz to 63 Hz
DC power input The CE5800 series, CE6810 series, CE6850-48S4Q-EI, CE6851-48S6Q-HI, CE6855-48S6Q-HI, CE6856-48S6Q-HI, CE6860-48S8CQ-EI, CE6865-48S8CQ-EI, CE6870-24S6CQ-EI, CE6870-48S6CQ-EI, CE6875-48S4CQ-EI, CE6880-24S4Q2CQ-EI, CE6880-48S4Q2CQ-EI, CE8860-4C-EI, CE8861-4C-EI, CE8868-4C-EI, and CE8850-64CQ-EI support DC power inputs:

  • Rated voltage range: -48 V DC to -60 V DC
  • Maximum voltage range: -38.4 V DC to -72 V DC
High-voltage DC power input
The CE8860-4C-EI, CE8861-4C-EI, CE8868-4C-EI, CE6850-48S6Q-HI, CE6850-48T6Q-HI, CE6855-48T6Q-HI, CE6856-48T6Q-HI, CE6850U-48S6Q-HI, CE6850U-24S2Q-HI, and CE6875-48S4CQ-EI support high-voltage DC power inputs:

  • Rated voltage range of 240 V high-voltage DC power input: 240 V DC
  • Maximum voltage range of 240 V high-voltage DC power input: 188 V DC to 290 V DC
  • Rated voltage range of 380 V high-voltage DC power input: 240 V DC to 380 V DC
  • Maximum voltage range of 380 V high-voltage DC power input: 188 V DC to 400 V DC
Rated input current
  • 150 W AC power module (PAC-150WA): 2.5 A (100 V AC to 240 V AC)
  • 150 W AC power module (ES0W2PSA0150): 3 A (100 V AC to 240 V AC)
  • 350 W AC power module (PAC-350WA series): 5 A (100 V AC to 240 V AC)
  • 350 W DC power module (PDC-350WA series): 11 A (-48 V DC to -60 V DC)
  • 600 W AC power module (PAC-600WA series): 9 A (100 V AC to 240 V AC)
  • 600 W AC&240 V DC power module (PAC-600WB series): 8 A (100 V AC to 240 V AC)/4 A (240 V DC)
  • 600 W high-voltage DC power module (PHD-600WA series): 4 A (240 V DC to 380 V DC)
  • 1200 W AC&240 V DC power module (PAC-1K2WA series): 10 A (100 V AC to 130 V AC)/8 A (200 V AC to 240 V AC)/8 A (240 V DC)
  • 1200 W high-voltage DC power module (PHD-1K2WA series): 8 A (240 V DC to 380 V DC)
  • 1200 W DC power (PDC-1K2WA series): 27 A (-48 V DC to -60 V DC)
Maximum power consumption Use the Hardware Configuration Tool to query the maximum power consumption of a switch.

As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei router and switch and all cards at very good price, also HongTelecom ship to worldwide with very fast delivery.

For related articles, visit the HongTelecom Blog and HongTelecom WordPress.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.

何诗名片

Electrical Safety about AC/DC Operation for Huawei CloudEngine (CE) 8800,7800, 6800, and 5800 Series switches

Huawei Data Center Switch includes CloudEngine CE12800, CE12800E, CE1800V, CE5800, CE6800, CE7800, CE8800 Series. In this article, HongTelecom will introduce the Electrical Safety about AC/DC Operation for CE12800& CE8800& CE7800& CE6800& CE5800 series switches.

Grounding

  • Ensure that the protection ground is reliably grounded in accordance with local building distribution specifications.
  • For equipment requiring grounding, always connect the protection ground first and disconnect it last when installing the equipment.
  • For the equipment using a socket with an earthing terminal, ensure that the earthing terminal is correctly grounded.

AC/DC Operation

 DANGER:
  • Do not contact the power system supply directly or indirectly through damp material. The hazardous voltage may cause electric shock.
  • Improper operation may cause accidents such as fire and electric shock.
  • This device relies on the building’s installed overcurrent protection from short circuits. Check that all specifications are compatible before equipment installation.For CE5850-48T4S2Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.For CE5850-48T4S2Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE5810-24T4S-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE5810-48T4S-EI,ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850-48S4Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850-48T4Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6810-48S4Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850-48S6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 400VDC, 20A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE7850-32Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6810-32T16S4Q-LI, ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6810-24S2Q-LI,ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6810-48S4Q-LI,ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6810-48S-LI,ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850-48S6Q-HI,ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850-48T6Q-HI,ensure that a fuse or circuit breaker no larger than 240VAC, 20 A(for AC type), 400VDC, 20A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6851-48S6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850U-48S6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 400VDC, 20A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6850U-24S2Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 400VDC, 20A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE5855-48T4S2Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE5855-24T4S2Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE8850-32CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE8850-64CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 25A(for AC type), 400VDC, 25A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE8860-4C-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 25A(for AC type), 400VDC, 25A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE8861-4C-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 25A(for AC type), 400VDC, 25A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE8868-4C-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 25A(for AC type), 400VDC, 25A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6855-48S6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6855-48T6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 400VDC, 10A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6856-48S6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6856-48T6Q-HI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 400VDC, 10A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6860-48S8CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6865-48S8CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6870-24S6CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6870-48S6CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6870-48T6CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6875-48S4CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 400VDC, 20A(for high-voltage DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6880-24S4Q2CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6880-48S4Q2CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type), 80VDC, 20A(for DC type) is used on the phase conductors that include all current-carrying conductors.

    For CE6880-48T4Q2CQ-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE7855-32Q-EI, ensure that a fuse or circuit breaker no larger than 240VAC, 20A(for AC type) is used on the phase conductors that include all current-carrying conductors.

    For CE12804, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module), 240Vdc, 20A(for each high-voltage DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12808, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module), 240Vdc, 20A(for each high-voltage DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12812, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module), 240Vdc, 20A(for each high-voltage DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12816, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module), 240Vdc, 20A(for each high-voltage DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12804S, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module), 240Vdc, 20A(for each high-voltage DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12808S, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module), 240Vdc, 20A(for each high-voltage DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12804E, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12808E, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module) is used on the phase conductors that include all current-carrying conductors.

    For CE12816E, ensure that a fuse or circuit breaker no larger than 240 Vac, 20A(for each AC supplied module), 60Vdc, 63A(for each DC supplied module) is used on the phase conductors that include all current-carrying conductors.

  • If the power input of the equipment is permanent, ensure that an easy-to access disconnection device is installed on the exterior of the equipment.
  • Use AC-supplied models for TN, TT power systems.
  • For DC-supplied models, use reinforced insulation or double insulation to isolate the DC source from the AC mains supply.
  • Before connecting equipment, disconnect the corresponding external-equipment circuit breaker.
  • Before connecting the load (electrical equipment) or battery cable, verify that the input voltage is within the rated voltage range of the equipment.
  • Before connecting the load (electrical equipment) or battery cable, check the cable and terminal polarities to avoid reverse connection.
  • Before powering on, verify that equipment electrical connections are correct.
  • If the device has more than one power supply, disconnect all of them when powering off the device.

 

As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei router and switch and all cards at very good price, also HongTelecom ship to worldwide with very fast delivery.

For related articles, visit the HongTelecom Blog and HongTelecom WordPress.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.

何诗名片

Huawei CloudEngine 6800 Series Data Center Switches

Product Appearance

The CE6800 comes in seventeen models:
Model and Appearance Description

CE6870-48T6CQ-EI

  • 48 x 10 GE BASE-T ports
  • 6 x 100 GE QSFP28 ports or 6 x 40 GE QSFP+ ports

CE6870-48S6CQ-EI

  • 48 x 10 GE SFP+ ports
  • 6 x 100 GE QSFP28 ports or 6 x 40 GE QSFP+ ports

CE6870-24S6CQ-EI

  • 24 x 10 GE SFP+ ports
  • 6 x 100 GE QSFP28 ports or 6 x 40 GE QSFP+ ports

CE6860-48S8CQ-EI

  • 48 x 25 GE SFP28 ports
  • 8 x 100 GE QSFP28 ports

CE6850U-48S6Q-HI

  • 48 x 10 GE SFP+ ports, or 2G/4G/8G FC ports
  • 6 x 40 GE QSFP+ ports

CE6855-48S6Q-HI

  • 48 x 10 GE SFP+ ports
  • 6 x 40 GE QSFP+ ports

CE6855-48T6Q-HI

  • 48 x 10 GE Base-T ports
  • 6 x 40 GE QSFP+ ports

CE6851-48S6Q-HI

  • 48 x 10 GE SFP+ ports
  • 6 x 40 GE QSFP+ ports

CE6850-48T6Q-HI

  • 48 x 10 GE Base-T ports
  • 6 x 40 GE QSFP+ ports

CE6850-48S6Q-HI

  • 48 x 10 GE SFP+ ports
  • 6 x 40 GE QSFP+ ports

CE6850-48S4Q-EI

  • 48 x 10 GE SFP+ ports
  • 4 x 40 GE QSFP+ ports

CE6810-48S4Q-LI

  • 48 x 10 GE SFP+ ports
  • 4 x 40 GE QSFP+ ports

CE6810-32T16S4Q-LI

  • 32 x 10 GE BASE-T ports
  • 16 x 10 GE SFP+ ports
  • 4 x 40 GE QSFP+ ports

CE6810-24S2Q-LI

  • 24 x 10 GE SFP+ ports
  • 2 x 40 GE QSFP+ ports

Product specifications

CE6870 Product Characteristics

Item CE6870-48T6CQ-EI CE6870-48S6CQ-EI CE6870-24S6CQ-EI
10 GE SFP+ ports NA 48 24
10 GE BASE-T 48 NA NA
100 GE QSFP28 ports 6 6 6
Switching Capacity 2.16 Tbit/s 2.16 Tbit/s 1.68 Tbit/s
Forwarding Rate 720 Mpps
Airflow Design Front-to-back or back-to-front
Device Virtualization iStack: For details about the configuration, please see:
http://support.huawei.com/onlinetoolsweb/virtual/en/dc/stack_index.html?dcb
Network Virtualization TRILL
VXLAN routing and bridging
BGP-EVPN
QinQ access VXLAN
IPv6 over VXLAN
SDN Agile Controller
VMware NSX
Network Convergence FCoE
DCBX, PFC, and ETS
Programmability Programming on the OPS
CE modules for Ansible released on open source websites
Traffic Analysis NetStream
sFlow
VLAN Adding access, trunk, and hybrid interfaces to VLANs
Default VLAN
QinQ
MUX VLAN
GVRP
ACL 20k (Ingress and Egress shared)
MAC Address Table Maximum: 750k
Dynamic learning and aging of MAC addresses
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
MAC address limiting based on ports and VLANs
ARP Maximum: 750k
ND Maximum: 96k
IPv4 FIB Maximum: 380k
IP Routing IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS
IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+
IPv6 FIB Maximum: 128k
IPv6 IPv6 Neighbor Discovery (ND)
Path MTU Discovery (PMTU)
TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6
Multicast FIB Maximum: 32k
Multicast IGMP, PIM-SM, PIM-DM, MSDP, and MBGP
IGMP snooping
IGMP proxy
Fast leave of multicast member interfaces
Multicast traffic suppression
Multicast VLAN
Reliability LACP
STP, RSTP, VBST, and MSTP
BPDU protection, root protection, and loop protection
Smart Link and multi-instance
DLDP
ERPS (G.8032)
VRRP, VRRP load balancing, and BFD for VRRP
BFD for BGP/IS-IS/OSPF/Static route
QoS Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority
Actions of ACL, CAR, re-marking, and scheduling
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR
Congestion avoidance mechanisms, including WRED and tail drop
Traffic shaping
Configuration and Maintenance Console, Telnet, and SSH terminals
Network management protocols, such as SNMP v1/v2c/v3
File upload and download through FTP and TFTP
BootROM upgrade and remote upgrade
802.3az Energy Efficient Ethernet (EEE)
Hot patches
User operation logs
ZTP
Security and Management 802.1x authentication
Command line authority control based on user levels, preventing unauthorized users from using commands
DoS, ARP, and ICMP attack defenses
Port isolation, port security, and sticky MAC
Binding of the IP address, MAC address, interface number, and VLAN ID
Authentication methods, including AAA, RADIUS, and HWTACACS
Remote Network Monitoring (RMON)
Dimensions (W x D x H) 442 mm x 420 mm x 43.6 mm 442 mm x 420 mm x 43.6 mm 442 mm x 420 mm x 43.6 mm
Weight (fully loaded) 9.8 kg (21.6 lb) 8.7 kg (19.2 lb) 8.5 kg (18.7 lb)
Environmental Parameters Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m)
Storage temperature: -40°C to 70°C (-40°F to 158°F)
Relative humidity: 5% RH to 95% RH, non-condensing
Operating Voltage AC: 90V to 290V AC: 90V to 290V
DC: -38.4V to -72V
AC: 90V to 290V
DC: -38.4V to -72V
Maximum Power Consumption 394W 333W 258W

CE6860 Product Characteristics

Item CE6860-48S8CQ-EI
SFP28 Ports 48
QSFP28 Ports 8
Switching Capacity 4,000 Gbit/s
Forwarding Rate 3,000 Mpps
Airflow Design Front-to-back or back-to-front
Device Virtualization iStack: For details about the configuration, please see:
http://support.huawei.com/onlinetoolsweb/virtual/en/dc/stack_index.html?dcb
M-LAG
Network Virtualization TRILL
VXLAN routing and bridging
BGP-EVPN
QinQ access VXLAN
IPv6 over VXLAN
SDN Agile Controller
VMware NSX
Network Convergence FCoE
DCBX, PFC
Programmability OPS
CE modules for Ansible released on open source websites
Traffic Analysis NetStream
sFlow
VLAN Adding access, trunk, and hybrid interfaces to VLANs
Default VLAN
QinQ
MUX VLAN
GVRP
ACL Ingress: 2,750; Egress: 1,000
MAC Address Table Maximum: 136k
Dynamic learning and aging of MAC addresses
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
MAC address limiting based on ports and VLANs
ARP Maximum: 84k
ND Maximum: 32k
IPv4 FIB Maximum: 128k
IP Routing IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS
IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+
IPv6 FIB Maximum: 64k
IPv6 IPv6 Neighbor Discovery (ND)
Path MTU Discovery (PMTU)
TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6
Multicast FIB Maximum: 8k
Multicast IGMP, PIM-SM, PIM-DM, MSDP, and MBGP
IGMP snooping
IGMP proxy
Fast leave of multicast member interfaces
Multicast traffic suppression
Multicast VLAN
MPLS Multiprotocol label switching
Reliability LACP
STP, RSTP, VBST, and MSTP
BPDU protection, root protection, and loop protection
Smart Link and multi-instance
DLDP
ERPS (G.8032)
VRRP, VRRP load balancing, and BFD for VRRP
BFD for BGP/IS-IS/OSPF/Static route
QoS Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority
Actions of ACL, CAR, re-marking, and scheduling
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR
Congestion avoidance mechanisms, including WRED and tail drop
Traffic shaping
Configuration and Maintenance Console, Telnet, and SSH terminals
Network management protocols, such as SNMP v1/v2c/v3
File upload and download through FTP and TFTP
BootROM upgrade and remote upgrade
802.3az Energy Efficient Ethernet (EEE)
Hot patches
User operation logs
ZTP
Security and Management 802.1x authentication
Command line authority control based on user levels, preventing unauthorized users from using commands
DoS, ARP, and ICMP attack defenses
Port isolation, port security, and sticky MAC
Binding of the IP address, MAC address, interface number, and VLAN ID
Authentication methods, including AAA, RADIUS, and HWTACACS
Remote Network Monitoring (RMON)
Dimensions (W x D x H) 442 mm x 420 mm x 43.6 mm
Weight (fully loaded) 8.8 kg (19.4 lb)
Environmental Parameters Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m)
Storage temperature: -40°C to 70°C (-40°F to 158°F)
Relative humidity: 5% RH to 95% RH, non-condensing
Operating Voltage AC: 90V to 290V
DC: -38.4V to -72V
Maximum Power Consumption 336W

CE6810 Product Characteristics

Item CE6810LI
CE6810-48S4Q-LI CE6810-32T16S4Q-LI CE6810-24S2Q-LI
10G Base-T Ports 0 32 0
SFP+ Ports 48 16 24
QSFP+ Ports 4 4 2
Switching Capacity 1.28 Tbit/s 1.28 Tbit/s 640 Gbit/s
Forwarding Rate 960 Mpps 960 Mpps 480 Mpps
Airflow Design Front-to-back or back-to-front
Device Virtualization iStack: For details about the configuration, please see:
http://support.huawei.com/onlinetoolsweb/virtual/en/dc/stack_index.html?dcb
Super Virtual Fabric (SVF): For details about the configuration, please see:
http://support.huawei.com/onlinetoolsweb/virtual/en/dc/svf_index.html?dcb
M-LAG
Traffic Analysis NetStream
sFlow
VLAN Adding access, trunk, and hybrid interfaces to VLANs
Default VLAN
QinQ
MUX VLAN
GVRP
ACL Ingress: 1,250
Egress: 500
Ingress: 1,250
Egress: 500
Ingress: 1,250
Egress: 500
MAC Address Table Maximum: 128k Maximum: 128k Maximum: 128k
Dynamic learning and aging of MAC addresses
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
MAC address limiting based on ports and VLANs
ARP (maximum) 1.5k 1.5k 1.5k
IPv4 FIB (maximum) 1.5k 1.5k 1.5k
IP Routing IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS
Multicast IGMP snooping
MLD snooping
Reliability LACP
STP, RSTP, VBST, MSTP
BPDU protection, root protection, and loop protection
Smart Link and multi-instance
DLDP, LLDP
ERPS (G.8032)
VRRP, VRRP load balancing, and BFD for VRRP
QoS Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority
Actions of ACL, CAR, re-marking, and scheduling
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR
Congestion avoidance mechanisms, including WRED and tail drop
Traffic shaping
Configuration and Maintenance Console, Telnet, and SSH terminals
Network management protocols, such as SNMP v1/v2c/v3
File upload and download through FTP and TFTP
BootROM upgrade and remote upgrade
802.3az Energy Efficient Ethernet (EEE)
Hot patches
User operation logs
ZTP
Security and Management 802.1x authentication
Command line authority control based on user levels, preventing unauthorized users from using commands
DoS, ARP, and ICMP attack defenses
Port isolation, port security, and sticky MAC
Binding of the IP address, MAC address, interface number, and VLAN ID
Authentication methods, including AAA, RADIUS, and HWTACACS
Remote Network Monitoring (RMON)
Dimensions (W x D x H) 442 mm x 600 mm x 43.6 mm 442 mm x 420 mm x 43.6 mm 442 mm x 600 mm x 43.6 mm
Weight (fully loaded) 10.4 kg (22.9 lb) 8.5 kg (18.7 lb) 10.1 kg (22.3 lb)
Environmental Parameters Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m)
Storage temperature: -40°C to 70°C (-40°F to 158°F)
Relative humidity: 5% RH to 95% RH, non-condensing
Operating Voltage AC: 90V to 290V
DC: -38.4V to -72V
Max. Power Consumption 238W 288W 171W

Ordering Information

  • Huawei CE6810-24S2Q-LI Switch(24-Port 10G SFP+,2-Port 40GE QSFP+,2*FAN Box,Port-side Intake,Without Power Module)
  • Huawei CE6810-24S2Q-LI Switch(24-Port 10G SFP+,2-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6810-24S2Q-LI Switch(24-Port 10G SFP+,2-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Intake)
  • CE6810-LI-B-B0C Huawei CE6810-24S2Q-LI Switch CE6810-LI-F-B0C (24-Port 10G SFP+,2-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • CE6810-EI-B00 Huawei CloudEngine 6800 Series Data Center Switch CE6800
  • CE6810-48S4Q-EI Huawei CE6810-48S4Q-EI Switch (48-Port 10G SFP+,4-Port 40G QSFP+,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6810-48S4Q-EI Switch (48-Port 10G SFP+,4-Port 40G QSFP+,2*FAN Box,Port-side exhaust,Without Power Module)
  • Huawei CE6810-48S4Q-EI Switch(48 Port SFP+,4 Port 40GE QSFP+)
  • CE6810-EI-48SFP-AC Huawei CE6810-48S4Q-EI Switch (2*AC Power Module,2*FAN Box,Port-side Intake)
  • CE6810-EI-B-B0A CE6810-LI-B00 Huawei CloudEngine 6800 Series Data Center Switch CE6800
  • CE6810-48S4Q-LI Huawei CE6810-48S4Q-LI Switch(48-Port 10G SFP+,4-Port 40GE QSFP+,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6810-48S4Q-LI Switch(48-Port 10G SFP+,4-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6810-48S4Q-LI Switch(2*AC Power Module,2*FAN Box,Port-side Intake)
  • CE6810-LI-B-B0A Huawei CE6810-48S4Q-LI Bundle CE6810-LI-B-B1A (With 4*40GE QSFP+ Optical Moduule,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6810-48S4Q-LI Bundle CE6810-LI-F-B1A (With 4*40GE QSFP+ Optical Moduule,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6800 Series Switch CE6810-48S-LI (48-Port 10GE SFP+, Without Fan and Power Module)
  • Huawei CE6810-48S-LI Switch(48-Port 10G SFP+,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6810-48S-LI Switch(48-Port 10G SFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6810-48S-LI Switch(2*AC Power Module,2*FAN Box,Port-side Intake) CE6810-LI-B-B0B Huawei CE6810-48S-LI Bundle CE6810-LI-B-B1B (With 2*40GE QSFP+&8*10GE SFP+ Optical Moduule,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6810-48S-LI Bundle CE6810-LI-F-B1B (With 2*40GE QSFP+&8*10GE SFP+ Optical Moduule,2*FAN Box,Port-side Exhaust,Without Power Module)
  • CE6810-LI-B01 Huawei CE6800 Series Switch CE6810-48S-LI (2*600W AC Power Module, 2*FAN Box, Port side exhaust)
  • CE6810-LI-B10 Huawei CE6800 Switch CE6810-LI Bundle 10 (CE6810-48S4Q-LI mainframe, 4*QSFP-40G-iSR4, Without Fan and Power Module)
  • CE6810-LI-B11 Huawei CloudEngine 6800 Series Data Center Switch
  • CE6810-48S-LI Huawei CE6800 Series Switch CE6810-48S4Q-EI (48-Port 10GE SFP+, 4-Port 40G QSFP+, Without Fan and Power Module)
  • Huawei CE6800 Series Switch CE6810-48S4Q-LI (48-Port 10GE SFP+, 4-Port 40G QSFP+, Without Fan and Power Module)
  • Huawei CE6800 Series Switch CE6810-32T16S4Q-LI (32-port 10GE RJ45, 16-Port 10GE SFP+, 4-Port 40G QSFP+, Without Fan and Power Module)
  • Huawei CE6810-32T16S4Q-LI Switch(32-Port 10G RJ45,16-Port 10G SFP+,4-Port 40G QSFP+,2*FAN Box,Port-side Intake,Without Power Module)
  • Huawei CE6810-32T16S4Q-LI Switch(32-Port 10G RJ45,16-Port 10G SFP+,4-Port 40G QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6810-32T16S4Q-LI Switch CE6810-LI-F-B00 (32-Port 10G RJ45,16-Port 10G SFP+,4-Port 40G QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • CE6855-HI-B-B0A Huawei CloudEngine 6800 Series Data Center Switch CE6855-48S6Q-HI
  • CE6855-HI-F-B0A Huawei CE6800 Switch CE6855-48S6Q-HI(48-Port 10G SFP+,6-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • Huawei CE6800 Series Switch CE6855-48S6Q-HI (48-Port 10G SFP+, 6-Port 40GE QSFP+, 2*FAN Box,Without Fan and Power Module)
  • Huawei CE6800 Series Switch CE6855-48T6Q-HI(48-Port 10GE RJ45, 6-Port 40GE QSFP+, 2*FAN Box, Without Fan and Power Module)
  • CE6855-HI-B-B00 Huawei CE6800 Series Switch CE6855-48T6Q-HI(48-Port 10GE RJ45, 6-Port 40GE QSFP+, 2*AC Power Module, 2*FAN Box, Port-side Intake)
  • CE6855-HI-F-B00 Huawei CE6800 Series Switch CE6855-48T6Q-HI(48-Port 10GE RJ45,6-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • Huawei CE6800 Series Switch CE6850-48S6Q-HI (48-Port 10GE SFP+, 6-Port 40GE QSFP+, Without Fan and Power Module)
  • CE6850-HI-B00 Huawei CE6800 Series Switch CE6850-48S6Q-HI(2*600W AC Power Module, 2*FAN Box, Port Side Exhaust)
  • Huawei CE6850-48S6Q-HI-B Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6850-48S6Q-HI-F Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6850-48S6Q-HI Switch CE6850-HI-B-B0A (2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6800 Series Switch CE6850-48S4Q-EI Switch (48-Port 10GE SFP+, 4-Port 40G QSFP+, Without Fan and Power Module)
  • CE6850-EI-B00 Huawei CE6800 Series Switch CE6850-48S4Q-EI Switch (2*350W AC Power Module, 2*FAN Box, Port side exhaust)
  • Huawei CE6850-48S4Q-EI-F Switch (48-Port 10G SFP+,4-Port 40G QSFP+,2*FAN Box,Port-side exhaust,Without Power Module)
  • Huawei CE6850-48S4Q-EI Switch CE6850-EI-B-B0A (2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6800 Series Switch CE6850-48T4Q-EI (48-port 10GE RJ45, 4-port 40G QSFP+, Without Fan and Power Module)
  • CE6850-EI-B01 Huawei CE6800 Series Switch CE6850-48T4Q-EI (2*600W AC Power Module, 2*FAN Box, Port side exhaust)
  • Huawei CE6850-48T4Q-EI-B Switch (48-Port 10G RJ45,4-Port 40G QSFP+,2*FAN Box,Port-side Intaket,Without Power Module)
  • Huawei CE6850-48T4Q-EI-F Switch (48-Port 10G RJ45,4-Port 40G QSFP+,2*FAN Box,Port-side exhaust,Without Power Module)
  • Huawei CE6850-48T4Q-EI Switch CE6850-EI-B-B00 (2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6800 Series Switch CE6850U-48S6Q-HI(48-Port 10GE SFP+, support 2/4/8G FC, 6-Port 40GE QSFP+, Without Fan and Power Module)
  • Huawei CE6850U-48S6Q-HI-B Switch(48-Port 10GE SFP+,support 2/4/8G FC,6-Port 40GE QSFP+,2*FAN Box,Port-side Intake,Without Power Module)
  • Huawei CE6850U-48S6Q-HI-F Switch(48-Port 10GE SFP+,support 2/4/8G FC,6-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6850U-48S6Q-HI Switch CE6850U-HI-B-B0A (48-Port 10GE SFP+,support 2/4/8G FC,6-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6850U-48S6Q-HI Switch CE6850U-HI-F-B0A (48-Port 10GE SFP+,support 2/4/8G FC,6-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • Huawei CE6800 Series Switch CE6850U-24S2Q-HI(24-Port 10GE SFP+, support 2/4/8G FC, 2-Port 40GE QSFP+, Without Fan and Power Module)
  • Huawei CE6850U-24S2Q-HI-B Switch(24-Port 10GE SFP+,support 2/4/8G FC,2-Port 40GE QSFP+,2*FAN Box,Port-side Intake,Without Power Module)
  • Huawei CE6850U-24S2Q-HI-F Switch(24-Port 10GE SFP+,support 2/4/8G FC,2-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6850U-24S2Q-HI Switch CE6850U-HI-B-B0B (24-Port 10GE SFP+,support 2/4/8G FC,2-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6850U-24S2Q-HI Switch CE6850U-HI-F-B0B (24-Port 10GE SFP+,support 2/4/8G FC,2-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • Huawei CE6800 Series Switch CE6851-48S6Q-HI (48-Port 10GE SFP+, 6-Port 40GE QSFP+, Without Fan and Power Module)
  • Huawei CE6851-48S6Q-HI-B Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,2*FAN Box,Port-side Intake,Without Power Module)
  • Huawei CE6851-48S6Q-HI-F Switch(48-Port 10G SFP+,6-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6851-48S6Q-HI Switch CE6851-HI-F-B0A (48-Port 10G SFP+,6-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • Huawei CE6800 Series Switch CE6850-48T6Q-HI (48-Port 10GE RJ45, 6-Port 40GE QSFP+, Without Fan and Power Module)
  • Huawei CE6850-48T6Q-HI-B Switch(48-Port 10GE RJ45,6-Port 40GE QSFP+,2*FAN Box,Port-side Intake,Without Power Module)
  • Huawei CE6850-48T6Q-HI-F Switch(48-Port 10GE RJ45,6-Port 40GE QSFP+,2*FAN Box,Port-side Exhaust,Without Power Module)
  • Huawei CE6850-48T6Q-HI Switch CE6850-HI-F-B00 (48-Port 10GE RJ45,6-Port 40GE QSFP+,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • Huawei Switch CE6860-48S8CQ-EI (48-Port 25GE SFP28, 8*100GE QSFP28, Without Fan and Power Module)
  • CE6860-EI-F-B00 Huawei Switch CE6860-48S8CQ-EI (48-Port 25GE SFP28, 8*100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Exhaust)
  • CE6860-EI-B-B00 Huawei Switch CE6860-48S8CQ-EI (48-Port 25GE SFP28, 8*100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Intake)
  • Huawei CE6800 Switch CE6870-48S6CQ-EI (48-Port 10GE SFP+, 6-Port 100GE QSFP28, Without Fan and Power Module)
  • CE6870-EI-F-B0A Huawei CE6800 Switch CE6870-48S6CQ-EI (48-Port 10GE SFP+, 6-Port 100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Exhaust)
  • CE6870-EI-B-B0A Huawei CE6800 Switch CE6870-48S6CQ-EI (48-Port 10GE SFP+, 6-Port 100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Intake)
  • Huawei CE6800 Switch CE6870-24S6CQ-EI (24-Port 10GE SFP+, 6-Port 100GE QSFP28, Without Fan and Power Module)
  • CE6870-EI-F-B0B Huawei CE6800 Switch CE6870-24S6CQ-EI (24-Port 10GE SFP+, 6-Port 100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Exhaust)
  • CE6870-EI-B-B0B Huawei CE6800 Switch CE6870-24S6CQ-EI (24-Port 10GE SFP+, 6-Port 100GE QSFP28, 2*AC Power Module, 2*FAN Box, Port-side Intake)
  • Huawei CE6800 Switch CE6880-48S4Q2CQ-EI (48*10G SFP+,6*40G QSFP+ or 44*10G SFP+, 4*40G QSFP+,2*100G QSFP28,Without Fan and Power Module)
  • CE6880-EI-F-B0A Huawei CE6800 Switch CE6880-48S4Q2CQ-EI(48*10G SFP+,6*40G QSFP+or 44*10G SFP+,4*40G QSFP+,2*100G QSFP28,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • CE6880-EI-B-B0A Huawei CE6800 Switch CE6880-48S4Q2CQ-EI (48*10G SFP+,6*40G QSFP+ or 44*10G SFP+, 4*40G QSFP+,2*100G QSFP28,2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6800 Switch CE6880-24S4Q2CQ-EI(24*10G SFP+,4*40G QSFP+,2*100G QSFP28, Without Fan and Power Module)
  • CE6880-EI-F-B0B Huawei CE6800 Switch CE6880-24S4Q2CQ-EI (24*10G SFP+,4*40G QSFP+,2*100G QSFP28, 2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • CE6880-EI-B-B0B Huawei CE6800 Switch CE6880-24S4Q2CQ-EI (24*10G SFP+,4*40G QSFP+,2*100G QSFP28, 2*AC Power Module,2*FAN Box,Port-side Intake)
  • Huawei CE6800 Switch CE6880-48T4Q2CQ-EI (48*10G RJ45,6*40G QSFP+ or 44*10G RJ45, 4*40G QSFP+,2*100G QSFP28,Without Fan and Power Module)
  • CE6880-EI-F-B00 Huawei CE6800 Switch CE6880-48T4Q2CQ-EI (48*10G RJ45,6*40G QSFP+ or 44*10G RJ45, 4*40G QSFP+,2*100G QSFP28,2*AC Power Module,2*FAN Box,Port-side Exhaust)
  • CE6880-EI-B-B00 Huawei CE6800 Switch CE6880-48T4Q2CQ-EI (48*10G RJ45,6*40G QSFP+ or 44*10G RJ45, 4*40G QSFP+,2*100G QSFP28,2*AC Power Module,2*FAN Box,Port-side Intake)

About Us

As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei CE5800/ CE7800/ CE8800/ S5300/ S2300/ S9300/ S1700/ S2700/ S5700/S6720/ S7700/ S9700/ S12700 all cards at very good price, also Hong Telecom Equipment Service LTD ship to worldwide with very fast delivery.